introduction:Analysis on the causes of various faults of domestic linear guide rail Failure mode:rust After the oil film wears off,water、Acid and alkali solutions will adhere directly to exposed metal parts,The decrease in lubricity will also lead to corrosion of the track,Rust can be the cause of early denudation。 Main cause of occurrence:Poor storage、Water soluble coolant intrusion、High humidity environment。 Failure mode:Aqueous solution corrosion Intrusion of water-soluble coolant,Lubrication and rust resistance will be reduced,Lead to linear guide rust。In turn, denudation occurs。
2018-11-03 Reading quantity 469
introduction:Bearing seat manufacturer technical instructor said,Bearing seat in the use of the following points to pay special attention to: 1、Bearing housing must be preheated during the beginning of production,Prevent the occurrence of turtle cracks caused by the sudden encounter of hot metal liquid in the cold bearing seat,More complex bearing seats can be used with a blowtorch,Liquefied gas,Good conditions with mold temperature machine,Simpler housings can be preheated using slow injection。 2、Clean the parting surface of the bearing seat,This is a lot of work,Its also easy to overlook,The operator should thoroughly clean the parting surface of the bearing seat with kerosene,Not only can prevent the bearing seat will not be crushed,And after cleaning,Adjustable shaft
2018-11-02 Reading quantity 291
introduction:When using Yintai linear guide rail, it is necessary to perform good lubrication and oil injection,If not fully lubricated,The friction between the rolling element and the rolling surface will increase during movement,And may be a major cause of shortened life span。The lubrication of Yintai linear guide rail can be divided into two ways: grease and lubricating oil,Lubrication methods are roughly divided into manual lubrication and automatic forced lubrication,Depending on the operating speed of the system、Use the environment and other requirements to make appropriate choices。
2018-11-02 Reading quantity 1031
introduction:Commonly used ceramic materials mainly include:metal(Transition metal or similar metal)With boron、carbon、silicon、nitrogen、A compound of nonmetallic elements such as oxygen,And compounds composed of non-metallic elements,Carbides and nitrides such as boron and silicon。 According to the different composition of its elements can be divided into:Oxide ceramics、Nitride ceramics、Carbide ceramics、Silicide ceramics and boride ceramics。In addition,Glass ceramics have also been widely used as structural materials in recent years。
2018-11-01 Reading quantity 344
introduction:What are the precautions for using the limit switch?Now the market ceiling switch products can be said to be more and more,But what about the cost performance of these products that many people are very concerned about this topic。Therefore, it is necessary to have a certain understanding of what the precautions for using the limit switch are before choosing to buy,It is important to choose the right limit switch and install it properly。
2018-10-31 Reading quantity 279
introduction:Delta inverter applications are very wide,The following is DeltaC2000The application of frequency converter in energy saving of air compressor has several advantages。 Air compressors are widely used in various industries,Mainly to provide the compressed air needed in the plant,Delta frequency converterC2000Series successfully used in air compressor industry,It can reduce the operating cost and energy consumption of the air compressor system,Increase in product competitiveness。
2018-10-30 Reading quantity 927
introduction:Input overvoltage The input parameters of the power mode are abnormal——Input overvoltage。This abnormally light will cause the system to fail to work properly,If its heavy, itll burn the circuit。So what are the reasons for the high input voltage? The output end is suspended or not loaded; The output load is light. Procedure,Lighter than10%Rated load of; The input voltage is high or interferes with the input voltage。 For this kind of problem,This can be done by adjusting the load on the output or by adjusting the input voltage range,The details are as follows: Make sure the output is not less than less10%Rated load of,If the actual circuit operation will have no-load phenomenon,Right at the output and connected to a rated power10%Dummy load of; Change the input voltage within a reasonable range,When there is interference voltage, consider merging at the input endTVSTube or pressure regulator。
2018-10-29 Reading quantity 328
introduction:This paper introduces the process of proximity switch integration:novice-Advanced development process。 The integration of proximity switch sensors is a process from low level to high level、The development process from simple to complex。When the integration technology is not yet able to integrate the sensitive elements of the proximity switch sensor and all the processing circuits together,People always choose the basics first、Simpler circuits that, when integrated, can greatly improve the performance of proximity switch sensors are integrated with sensing or converting elements。
2018-10-27 Reading quantity 464
introduction:New glass micro-melting pressure sensor
2018-10-26 Reading quantity 206
introduction:The principle of home touch switch Touch switch is intelligent control switch,It is mounted on the wall,You can control it with the touch of your finger,The power consumption is very small。The key principle of touch switch is touch sensing,Switch control with touch sensing panel。Touch sensing we are familiar with touch screen mobile phones,Touch switches use the same technology。
2018-10-26 Reading quantity 240