introduction:Worm gear reducer is a power transmission mechanism,Speed converters using gears,Switch machine(motor)The number of turns slows down to the desired number of turns,And get a larger torque mechanism。In the mechanism currently used to transmit power and motion,The application range of reducer is quite wide。
2016-04-14 Reading quantity 231
introduction:Gear reducer is the use of all levels of gear transmission to achieve the purpose of reducing speed.The reducer is composed of gear pairs at all levels.For example, using small gears to drive large gears can achieve a certain goal of deceleration,Then adopt the multi-level structure,You can significantly reduce the RPM。
2016-04-14 Reading quantity 400
introduction:Cycloidal pin gear reducer principle The principle is like two silver coins,One stands still and the other leans on its side,When a rotating coin goes from one point back to the original point, it has gone two turns instead of one turn。
2016-04-14 Reading quantity 374
introduction:Xiwei inverter maintenance,When the Siwei inverter encounters a failure,Maintenance is about to take place,Can repair the common faults of Siwei inverter:No display、Phase loss、overcurrent、overvoltage、undervoltage、superheating、Over duty、Ground connection、Parameter error、There is no output、Module failure;
2016-04-14 Reading quantity 238
introduction:Principle of frequency converter speed regulation,The working principle of the inverter is to control the main circuit through the control circuit,A rectifier in the main circuit converts alternating current to direct current,The DC intermediate circuit smooths the DC current,The inverter finally converts the direct current back into alternating current at the desired frequency and voltage,Some inverters will also...
2016-04-14 Reading quantity 220
introduction:Japan Fuji inverter wiring diagram,Inverter power output terminalU、V、Wexpression。Determine the forward or reverse rotation according to the requirements of use,If the turn is wrong,You can switch the two phases at will。Capacitors and surge absorbers are strictly prohibited at the output end。The connection with the motor should not be too long,The pair power is not greater than3.7kWthe...
2016-04-14 Reading quantity 333
introduction:Type selection of turboworm reducer
2016-04-13 Reading quantity 240
introduction:Methods for selecting industrial sensors
2016-04-13 Reading quantity 213
introduction:Frequency converter specification,For Siemens inverter setup method,First get the inverter,SelectpKey to enter the Settings page,Then select the up and down buttons to select the options you want to set,Then the other factors of the Siemens inverter are set in the same way,After setting the desired options,According to theFnSave this...
2016-04-13 Reading quantity 264