introduction:1、Easy to use; 2、System sensitive and reliable; 3、Safe and durable equipment; 4、Can accurately distinguish owned vehicles、Exotic vehicles and special vehicles; 5、Instantly collect parking fees and other related fees,Increase income;
2018-11-20 Reading quantity 412
introduction:Electric lubrication pump out of oil how to do,Lubrication How did the manufacturer tell you to fill the oil。 1.Electric lubrication pump unscrew the bolts above the fueling valve,Add the right amount of oil,To not more than simplified3/4Be appropriate,Reserve some space to store compressed air to maintain the necessary air pressure。 2.Tighten the bolts of the fuel filler port after filling the oil,Close the stem of the oil drain valve,Wipe off any lubricating oil or kerosene spilled on the outside,And check whether there is leakage throughout the blowtorch。
2018-11-19 Reading quantity 798
introduction:In general industrial production sites,Eddy current access switches and capacitive access switches are usually used。Because these two proximity switches have lower environmental requirements。 When the object to be measured is a conductive object or an object that can be fixed to a metal object,Generally, vortex proximity switches are used,Because of its high response frequency、Good resistance to environmental interference、Wide application range、Lower price。 If the measured object is non-metallic(Or metal)、Liquid level height、Powder height、plastic、tobacco。Capacitive proximity switch should be used。The response frequency of this switch is low,But stable。Environmental factors should be considered during installation。
2018-11-19 Reading quantity 267
introduction:Division time,Loosen the spindle locking handle beforehand,Re-lock after indexing,But when machining the helical workpiece,Because the dividing head spindle should be rotated during the workpiece process,So you cant lock the spindle。To approach insist it clean,Before use, the bottom surface of the device, the spindle cone hole and the milling machine table should be wiped clean。Check time,The exposed metal surface should be coated with oil to prevent rust。 Always pay attention to the local smoothness of the dividing head,And follow the rules set out in the book,Refuel regularly。When holding the workpiece at the indexing head,To lock the dividing head spindle first。Do not exert too much force when tightening,Never hit the workpiece hard。Division time,Its usually shaken in a clockwise direction,In the process of shaking,Be as constant and even as possible。Once the position is over, the dividing handle should be returned more than half a turn to eliminate the gap,Then gradually insert the positioning pin in the
2018-11-17 Reading quantity 464
introduction:Installation tips on switch panel 1、The installation position of the switch panel cannot have more than two tiles,And try to make it installed in the middle of the tile。 2、When the bottom box of the switch panel is opened,The border cannot be larger than the bottom box2mmabove,You cant make a round hole。This will ensure that the switch is installed later、socket,Bottom box as flat as possible with tile,Later installation will not need to find a longer screw,It cannot be installed on the flower piece and waist line of the tile。 3、To make a hole in the faucet, you must make a round hole,Do not make square holes,And its not gonna work"U"type,The size of the opening shall not exceed the diameter of the pipe2mmabove,And the edge of the water outlet must also be flush with the tile。
2018-11-16 Reading quantity 314
introduction:indexingz=35。The number of revolutions of the handle at each indexing is: n=40/z=40/35=1again1/7。That is, once every minute,Handle needs to be turned1again1/7 turn。this1/7The rotation is controlled by the index dial,The general dividing head is equipped with two dividing plates。There are many holes on both sides of the index plate,The number of holes in each ring is different,But the hole spacing on the same hole ring is the same。 The number of holes in each circle on the front of the first index plate is24、25、28、30、34、37;The reverse side is38、39、41、42、43,The number of holes in each circle on the front of the second dividing plate is46、47、49、51、53、54;The reverse are respectively57、58、59、62、66。Simple indexing time,The index plate is fixed。At this point, pull out the positioning pin on the index plate,Adjust the number of holes to7Multiple of the holes on the ring,namely28、42、49Both can。If you choose42Hole number,namely1/7=6/42。therefore,Division time,Once the handle is turned,The number of further holes is42Tu
2018-11-13 Reading quantity 571
introduction:What are the precautions for using the limit switch?Now the market ceiling switch products can be said to be more and more,But what about the cost performance of these products that many people are very concerned about this topic。Therefore, it is necessary to have a certain understanding of what the precautions for using the limit switch are before choosing to buy,It is important to choose the right limit switch and install it properly。
2018-10-31 Reading quantity 279
introduction:Delta inverter applications are very wide,The following is DeltaC2000The application of frequency converter in energy saving of air compressor has several advantages。 Air compressors are widely used in various industries,Mainly to provide the compressed air needed in the plant,Delta frequency converterC2000Series successfully used in air compressor industry,It can reduce the operating cost and energy consumption of the air compressor system,Increase in product competitiveness。
2018-10-30 Reading quantity 927
introduction:Input overvoltage The input parameters of the power mode are abnormal——Input overvoltage。This abnormally light will cause the system to fail to work properly,If its heavy, itll burn the circuit。So what are the reasons for the high input voltage? The output end is suspended or not loaded; The output load is light. Procedure,Lighter than10%Rated load of; The input voltage is high or interferes with the input voltage。 For this kind of problem,This can be done by adjusting the load on the output or by adjusting the input voltage range,The details are as follows: Make sure the output is not less than less10%Rated load of,If the actual circuit operation will have no-load phenomenon,Right at the output and connected to a rated power10%Dummy load of; Change the input voltage within a reasonable range,When there is interference voltage, consider merging at the input endTVSTube or pressure regulator。
2018-10-29 Reading quantity 329
introduction:This paper introduces the process of proximity switch integration:novice-Advanced development process。 The integration of proximity switch sensors is a process from low level to high level、The development process from simple to complex。When the integration technology is not yet able to integrate the sensitive elements of the proximity switch sensor and all the processing circuits together,People always choose the basics first、Simpler circuits that, when integrated, can greatly improve the performance of proximity switch sensors are integrated with sensing or converting elements。
2018-10-27 Reading quantity 464