introduction:ctFrequency converter advantage: 1、mightySMApplication module option, The implementation of various engineering schemes to meet all user schemes. Conform toIEC61131-3Industry standard。 2、Extremely fast speed and current updates, Ensures optimal dynamic response。 3、Multi-axis motion interlocking control application, driverSynchronization control with the drive。 4、passCTNETNetwork to achieve decentralized control。 5、The dynamic update rate can reach250us 6、Truly systematic driver, Make customer solutions scalable。 ctMore efficient frequency converter: 1、built-inEMCfilter, Conform toEN61800-3Electromagnetic compatibility standard。 2、StandardSDFeatures Reduce system costs,Conform toEN954-1Lv.3Standard。 3、StandardModbus RTUport 4、Built-in smart card,Parameter backup can be automatically completed, Make debugging safer and faster。 5、Only one training,You can master and master all driver types。 6、3An interpolation typeSMApplication module, Make the drive truly upgradeablePLCFeature。 7、For a variety of applications
2017-07-20 Reading quantity 219
introduction:First of all, we must know that inverter maintenance is a theoretical knowledge、Work with a combination of practical experience and operational level,Its technical level determines the maintenance quality of the inverter。Engaged in frequency converter maintenanceThe personnel need to learn often,Understand the functions and characteristics of the electronic components inside the inverter,Broaden the scope of knowledge,Apply the newly acquired knowledge to practical work,Constantly improve the level of maintenance technology。 Some inverter maintenance basic knowledge is we need to understand,Such as the following: Technological development: Dc electric drive and AC motor drive were born19century,Already have100Years of history,And has become the main driving device of power machinery。Due to technical problems at the time,In a long time,The need for speed control in the drag system is basically the use of DC motor。
2017-07-20 Reading quantity 172
introduction:TaiwanabbaHow to install linear guide rail? ABBALinear guide(ABBALinear)Is ** standard line technology Co., Ltd. production。Be established in1999Since its establishment,It is the first professional linear slide manufacturer in Taiwan with a four-row bead self-moistening patent and actually introduced into mass production。International linear technology accumulated 18 years of precision ball screw manufacturing experience,Master the core and key technologies,Combined with Taiwan University of Science and Technology linear ball slide research and development capabilities,Go smoothly with2000Complete the mass production plan every year,And obtained a number of world patents·Successfully introduce products to the world stage,Currently has its own brand distribution network throughout Taiwan、mainland、Korea、Japan、Europe and America。 ABBASince its inception,Constantly strive to take root in the market and product quality,Won the ninth Innovative Research Award、2002and2004Taiwan Excellence Award、The 6th Littl
2017-07-19 Reading quantity 289
introduction:abbaLinear guide maintenance abbaHigh positioning accuracy when using linear guide rails as linear guidance,Because the friction mode of linear guide rail is rolling friction,Not only is the friction coefficient reduced to slide-guided1/50,The difference between dynamic friction and static friction force also becomes very small。So when the bed is running,There will be no slippage,attainabilityμmLevel of positioning accuracy。Traditional slide guidance with less wear can maintain accuracy for a long time,It is inevitable that the platform movement precision will be poor due to the greasy countercurrent action,And due to insufficient lubrication during exercise,It causes the wear of the contact surface of the running track,Seriously affect accuracy。The wear of the rolling guide is very small,Therefore, the machine can maintain accuracy for a long time。 Linear guide cleaning and maintenance: rail、The linear shaft is one of the core components of the equipment,Its function is to guide and support。In order to e
2017-07-19 Reading quantity 74
introduction:Variable frequency control cabinetIt is controlled by the built-in frequency converter and the periphery,Protection,Display and other electrical components and cabinet composition,Is a three-phase AC motor(Including fan,pump)Ac drive device and energy-saving device for frequency conversion speed control。Frequency conversion control cabinet is used50Hz、Network voltage380V、Capacity from0.75~630KWSpeed regulation and operation of three-phase asynchronous motor。Variable frequency control cabinet with high power factor,Constant torque performance(Below fundamental frequency)Programmed speed control,Up.、Lower limit speed control,is、Reverse control,Automatic stepless speed regulation and motor short circuit、Over duty、overvoltage、Undervoltage and other protection functions。Motor operating current、The operating frequency of the motor is displayed,Concurrent output4~20mAStandard signal,Easy to work with computer networking。Frequency conversion control cabinet adopts closed cabinet structure,The protection level is gen
2017-07-18 Reading quantity 218
introduction:Frequency converter distribution area is relatively broad,Such as Beijing and other places,So when the frequency converter fails,Many places cannot be repaired in time due to geographical relations,Today, Xiaobian will introduce you to the maintenance of the inverterknowledge,Let those confused friends find a way out! Some common methods: Static testing: 1、Test the rectifier circuit Find the result,It can be determined that the circuit has an anomaly,A.To the inverter internal DC power supplyPEnd sumNend,Set the multimeter to resistanceX10file,Red watch rod connectedP,Black watch rod separately under toR、S、T,Normally, it has a resistance value of tens of ohm,And basically balanced。Instead connect the black watch rodPend,The red watch rod is connected in turnR、S、T,There is a resistance that is close to infinity。Attach the red watch rodNend,Repeat the above steps,They should all get the same result。If there is a three-phase unbalance to the resistance value,The rectifier bridge is faulty.B.Red watch rod co
2017-07-18 Reading quantity 299
introduction:abbaLinear Guide Official website describes the features of the guide ABBASince its inception,Constantly strive to take root in the market and product quality,Won the ninth Innovative Research Award、2002and2004The 6th Little Giant Awards、The 6th Little Giant Awards、And the second new business Silver Award,In addition,It has also been approved by the Industry Bureau of the Ministry of Economic Affairs to reward investment in emerging important strategic industries,Confirms that International Straight Lines efforts over the past five years have gained customers、Manufacturers and industry, government and academic circles consistent affirmation and support。SKFThe group was established in1907years,Is the worlds leading rolling bearings and seals、mechatronics、oiling、Provider of services and solutions。 ABBALinear guide characteristics: High positioning accuracy when using linear guide rails as linear guidance,Because the friction mode of linear guide rail is rolling friction,Not only is the friction coefficient
2017-07-18 Reading quantity 258
introduction:four75kΩ2WThe resistor undertakes the task of transmitting the starting current of the power supply,After the power supply is energized,IC201The power supply is provided by the output voltage of the self-powered windingD215、C236Rectifier filter into DC voltage supply。After power on,IC201the8Pin output5VReference voltage,Except provide8、4interpeduncularR、COscillating timing circuit outside the power supply,Voltage regulation control circuit is also providedPC9The power supply of the output side triode;IC201the1、2The feet are connected in parallelR、D、Cisoelement,The feedback loop of the internal voltage error amplifier is formed,The gain and frequency transmission characteristics of the amplifier are determined;6Inside footPWMWave forming circuit,Oscillating pulse6Pin output,byR241、ZD204Noise cancellation and positive limiting,theR240Add to switch tubeTR1Grid of,TR1Turn-on of,A switching transformer is formedTL1The current in the primary winding,TL1The self-powered winding、The secondary winding then generates a
2017-07-17 Reading quantity 199
introduction:Inverter maintenance is a theoretical knowledge、Work with a combination of practical experience and operational level,Its technical level determines the maintenance quality of the inverter。Engaged in frequency converter maintenanceThe personnel need to learn often,Understand the functions and characteristics of the electronic components inside the inverter,Broaden the scope of knowledge,Apply the newly acquired knowledge to practical work,Constantly improve the level of maintenance technology。 Inverter overcurrent protection and maintenance technology: In the frequency converter maintenance,The object of overcurrent protection mainly refers to the mutability、The condition in which the peak current exceeds the allowable value of the frequency converter. Because the overload capacity of the inverter is poor,Therefore, the overcurrent protection of the inverter is a crucial part,So far,It has been well developed.
2017-07-17 Reading quantity 303
introduction:abbaLinear guide agent teach you how to distinguish between true and false abbaThe function of linear guide is to support and guide moving parts,Reciprocating straight motion in the given direction。It depends on the frictional nature,Linear motion guides can be divided into sliding friction guides、Rolling friction guide、Elastic friction guide、Fluid friction guide and other types。 Linear bearings are mainly used in automated machinery,Like machine tools imported from Germany,Bending machine,Laser welding machine and so on,Of course, linear bearings and linear shafts are used together。Linear guides are mainly used in mechanical structures with high precision requirements,No intermediate medium is used between the moving element and the fixed element of the linear guide,And use rolling steel balls。 1---Slide rail Early stage(At least09Years ago)Arc grinding marks are visible on the upper surface of the slide rail,Bottom ground on both sides,The indentation in the middle is black without grinding。 2---Sliding blo